aut.vn Đồng hồ nhiệt Omron E5AC-QR4ASM-009
aut.vn Đồng hồ nhiệt Omron E5AC-QR4ASM-009
Digital Temperature Controller
96 x 96 mm
Voltage output (for driving SSR)/Relay output
Auxiliary output: 4
Power supply voltage: 100 to 240 VAC
Universal inputs
HB alarm and HS alarm: 2
RS-485
2 event inputs
Screw terminal block model
Mua Ngay :
Giá cũ: 1.000 ₫
100 ₫
aut.vn Đồng hồ nhiệt Omron E5AC-QR4ASM-009
Shape : DIN 96 x 96
Terminal type : Screw terminal block
Input type : Thermocouple/Platinum resistance thermometer/Infrared Thermosensor/Analog input
Control output 1 : Voltage output (for driving SSR)
Control output 2 : Relay output
Number of total auxiliary output : 4 point
Power supply voltage : 100 to 240 VAC (50/60 Hz)
Number of event input : 2 point
Heater burnout /SSR failure detector : 2 points
Communications method : RS-485 (two-wire, half duplex)
Shape : DIN 96 x 96
Fixed/Programmable : Fixed
Power supply voltage : 100 to 240 VAC (50/60 Hz)
Allowable voltage variable range : 85 to 110% of the power supply voltage
Power consumption : 9 VA max. (at 100 to 240 VAC)
Input : Number of input points : 1 point
Temperature input : Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII
Platinum resistance thermometer: Pt100, JPt100
Infrared Thermosensor: 10 to 70 ℃, 60 to 120 ℃, 115 to 165 ℃, 140 to 260 ℃
Analog input : 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V
Input impedance : Current input: 150 Ω max., voltage input: 1 MΩ min. (Applicable when connecting 1:1 to ES2-HB-N/THB-N.)
Control method : ON/OFF or 2-PID control with auto-tuning
Control output : Number of total control output : 2 point
Control output 1 : Voltage output (for driving SSR)
Control output 2 : Relay output
Relay output : 1 point
SPST-NO, 250 VAC, 5 A (resistive load)
Minimum applicable load: 10 mA at 5 V
Voltage output (for driving SSR) : 1 point
12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit
Auxiliary output : Number of total auxiliary output : 4 point
Relay output : SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations (minimum applicable load: 5 V, 10 mA)
Event input : 2 point
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
No-contact input: ON: Residual voltage 1.5 V max., OFF: Leakage current 0.1 mA max.
Current flow: Approx. 7 mA per point
Setting method : Digital setting using front panel keys
Indication method : 11-segment digital display and individual indicators
Multi SP functions : Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications.
Sampling period : 50 ms
Hysteresis : Temperature input: 0.1 to 999.9 ℃ or °F (in units of 0.1 ℃ or °F)
Analog input: 0.01 to 99.99% FS (in units of 0.01% FS)
Proportional band : Temperature input: 0.1 to 999.9 ℃ or °F (in units of 0.1 ℃ or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
Derivative time : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
for cooling : Proportional band (P) : Temperature input: 0.1 to 999.9 ℃ or °F (in units of 0.1 ℃ or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
Derivative time (D) : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
Control period : 0.1 s, 0.2 s, 0.5 s, 1 to 99 s (in units of 1 s)
Manual reset value : 0.0 to 100.0% (in units of 0.1%)
Insulation resistance : 20 MΩ min. (at 500 VDC)
Dielectric strength : 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of different polarity)
Vibration resistance : Destruction: 10 to 55 Hz, 20 m/s2 for 2 h each in X, Y, and Z directions
Malfunction: 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Shock resistance : Destruction: 300 m/s2, 3 times each in X, Y, and Z directions
Malfunction: 100 m/s2, 3 times each in X, Y, and Z directions
Ambient temperature (Operating) : -10 to 55 ℃ (with no freezing or condensation)
For 3-year warranty with standard mounting: -10 to 50 ℃ (with no freezing or condensation)
Ambient temperature (Storage) : -25 to 65 ℃ (with no freezing or condensation)
Ambient humidity (Operating) : 25 to 85 %
Altitude : 2000 m max.
Degree of protection : Front panel: IP66, Rear case: IP20, Terminal section: IP00
Memory protection : Non-volatile memory (number of writes: 1,000,000)
Case color : Black
Terminal type : Screw terminal block
Accessories : Mounting adapter, Waterproof packing, Front Port Cover
Weight : Main Unit: Approx. 250 g
Adapter: Approx. 4 g x 2
Sold separately : USB Serial Conversion Cable: E58-CIFQ2
Communications Conversion Cable: E58-CIFQ2-E
Terminal Cover: E53-COV24
Waterproof packing: Y92S-P10
Waterproof Cover: Y92A-96N
Front Port Cover: Y92S-P7
Adapter: Y92F-51
CX-Thermo Support Software: EST2-2C-MV4
Current Transformer (CT): E54-CT1/E54-CT1L/E54-CT3/E54-CT3L
Indication accuracy : Thermocouple: (±0.3% of indicated value or ±1 ℃, whichever is greater) ±1 digit max.
Platinum resistance thermometer: (±0.2% of indicated value or ±0.8 ℃, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
(The indication accuracy of K thermocouples in the -200 to 1300 ℃ range, T and N thermocouples at a temperature of -100 ℃ max., and U and L thermocouples at any temperatures is ±2 ℃ ±1 digit max. B thermocouple at a temperature of 400 ℃ max. is not specified. B thermocouples in the 400 to 800 ℃ range is ±3 ℃ max. R and S thermocouples at a temperature of 200 ℃ max. is ±3 ℃ ±1 digit max. C/W thermocouples is (±0.3% PV or ±3 ℃, whichever is greater) ±1 digit max. PL II thermocouples is (±0.3% PV or ±2 ℃, whichever is greater) ±1 digit max.)
Influence of temperature/voltage : Thermocouple: R, S, B, C/W, and PLII: (±1% of indicated value or ±10 ℃, whichever is greater) ±1 digit max.
Others: (±1% of indicated value or ±4 ℃, whichever is greater) ±1 digit max.. However K thermocouple at -100 ℃ max.: ±10 ℃ max.
Platinum resistance thermometer: (±1% of indication value or ±2 ℃, whichever is greater) ±1 digit max.
Analog input: ±1% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Ambient temperature: -10 to 23 to 55 ℃, Voltage range: -15 to 10% of rated voltage
Influence of EMS. : Thermocouple: R, S, B, C/W, and PLII: (±1% of indicated value or ±10 ℃, whichever is greater) ±1 digit max.
Others: (±1% of indicated value or ±4 ℃, whichever is greater) ±1 digit max.. However K thermocouple at -100 ℃ max.: ±10 ℃ max.
Platinum resistance thermometer: (±1% of indication value or ±2 ℃, whichever is greater) ±1 digit max.
Analog input: ±1% FS ±1 digit max.
Influence of signal source resistance : Thermocouple: 0.1℃/Ω max. (100 Ω max.)
Platinum resistance thermometer: 0.1℃/Ω max. (10 Ω max.)
Transmission path connection : Multidrop (RS-485)
Communications method : RS-485 (two-wire, half duplex)
Synchronization method : Start-stop synchronization
Protocol : CompoWay/F, Modbus
Communication speed : 9600, 19200, 38400, 57600 bps
Transmission code : ASCII
Data bit length : 7 or 8 bits
Stop bit length : 1 or 2 bits
Error detection : Vertical parity (none, even, odd)
Block check character (BCC) with CompoWay/F
CRC-16 Modbus
Flow control : None
Interface : RS-485
Retry function : None
Communications buffer : 217 bytes
Communications response send delay : 0 to 99 ms (Default: 20 ms)
Programless communications function : You can use the memory in the PLC to read and write E5□C parameters, start and stop operation, etc. The E5□C automatically performs communications with PLCs. No communications programming is required.
Number of connected Digital Temperature Controllers: 32 max. (Up to 16 for the FX Series)
Component communications : When Digital Temperature Controllers are connected, set points and RUN/STOP commands can be sent from the Digital Temperature Controller that is set as the master to the Digital Temperature Controllers that are set as slaves. Slope and offsets can be set for the set point.
Number of connected Digital Temperature Controllers: 32 max. (including master)
Copying : When Digital Temperature Controllers are connected, the parameters can be copied from the Digital Temperature Controller that is set as the master to the Digital Temperature Controllers that are set as slaves.
CT input (for heater current detection) : 2 points
Max. heater current : Single-phase or Three-phase 50 A AC
Input current indication accuracy : ±5% FS ±1 digit max.
Heater burnout alarm setting range : 0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms (The value is 30 ms for a control period of 0.1 s or 0.2 s)
SSR failure detector alarm setting range : 0.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms (The value is 35 ms for a control period of 0.1 s or 0.2 s)
Chúng tôi có hơn 35.000 sản phẩm vì vậy hãy liên hệ với chúng tôi
Để được tư vấn và check tình trạng hàng bạn nhé!
AUTO TECH VN cam kết:
1. Hàng Chính Hãng Autonics Việt Nam.
2. Xuất được Hóa đơn VAT.
3. Cấp CO/CQ công chứng bởi Autonics Vina.
4. Giá cạnh tranh.
5. Sản phẩm bảo hành theo chính sách của hãng.
AUTO TECH VN - AUT.VN
Thông tin liên hệ
ĐT/ Zalo : 0968.053.025
Email: support@aut.vn Email2: sale@aut.vn
Địa chỉ: 07 KĐT Flora Mizuki, Đường Số 1, Bình Hưng, Bình Chánh, Hồ Chí Minh