aut.vn Đồng hồ nhiệt Omron E5AC-QR2DSM-000

aut.vn Đồng hồ nhiệt Omron E5AC-QR2DSM-000
Digital Temperature Controller
96 x 96 mm
Voltage output (for driving SSR)/Relay output
Auxiliary output: 2
Power supply voltage: 24 VAC/VDC
Universal inputs
No options
Screw terminal block model



Mua Ngay : Zalo

nhà chế tạo: Omron
SKU: E5AC-QR2DSM-000
Ngày giao hàng: 3-5 days
Giá cũ: 1.000 ₫
100 ₫
Giao đến
*
*
Phương pháp vận chuyển
Tên
Ngày dự kiến giao hàng
Giá bán
Không có tùy chọn giao hàng nào
aut.vn Đồng hồ nhiệt Omron E5AC-QR2DSM-000

Shape : DIN 96 x 96
Terminal type : Screw terminal block
Input type : Thermocouple/Platinum resistance thermometer/Infrared Thermosensor/Analog input
Control output 1 : Voltage output (for driving SSR)
Control output 2 : Relay output
Number of total auxiliary output : 2 point
Power supply voltage : 24 VAC (50/60 Hz)
24 VDC
Shape : DIN 96 x 96
Fixed/Programmable : Fixed
Power supply voltage : 24 VAC (50/60 Hz)
24 VDC
Allowable voltage variable range : 85 to 110% of the power supply voltage
Power consumption : 2.4 W max. (at 24 VDC)
4.2 VA max. (at 24 VAC)
Input : Number of input points : 1 point
Temperature input : Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, PLII
Platinum resistance thermometer: Pt100, JPt100
Infrared Thermosensor: 10 to 70 ℃, 60 to 120 ℃, 115 to 165 ℃, 140 to 260 ℃
Analog input : 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V
Input impedance : Current input: 150 Ω max., voltage input: 1 MΩ min. (Applicable when connecting 1:1 to ES2-HB-N/THB-N.)
Control method : ON/OFF or 2-PID control with auto-tuning
Control output : Number of total control output : 2 point
Control output 1 : Voltage output (for driving SSR)
Control output 2 : Relay output
Relay output : 1 point
SPST-NO, 250 VAC, 5 A (resistive load)
Minimum applicable load: 10 mA at 5 V
Voltage output (for driving SSR) : 1 point
12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit
Auxiliary output : Number of total auxiliary output : 2 point
Relay output : SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations (minimum applicable load: 5 V, 10 mA)
Setting method : Digital setting using front panel keys
Indication method : 11-segment digital display and individual indicators
Multi SP functions : Up to eight set points (SP0 to SP7) can be saved and selected using key operations.
Sampling period : 50 ms
Hysteresis : Temperature input: 0.1 to 999.9 ℃ or °F (in units of 0.1 ℃ or °F)
Analog input: 0.01 to 99.99% FS (in units of 0.01% FS)
Proportional band : Temperature input: 0.1 to 999.9 ℃ or °F (in units of 0.1 ℃ or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
Derivative time : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
for cooling : Proportional band (P) : Temperature input: 0.1 to 999.9 ℃ or °F (in units of 0.1 ℃ or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Integral time (I) : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
Derivative time (D) : 0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s)
Control period : 0.1 s, 0.2 s, 0.5 s, 1 to 99 s (in units of 1 s)
Manual reset value : 0.0 to 100.0% (in units of 0.1%)
Insulation resistance : 20 MΩ min. (at 500 VDC)
Dielectric strength : 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of different polarity)
Vibration resistance : Destruction: 10 to 55 Hz, 20 m/s2 for 2 h each in X, Y, and Z directions
Malfunction: 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Shock resistance : Destruction: 300 m/s2, 3 times each in X, Y, and Z directions
Malfunction: 100 m/s2, 3 times each in X, Y, and Z directions
Ambient temperature (Operating) : -10 to 55 ℃ (with no freezing or condensation)
For 3-year warranty with standard mounting: -10 to 50 ℃ (with no freezing or condensation)
Ambient temperature (Storage) : -25 to 65 ℃ (with no freezing or condensation)
Ambient humidity (Operating) : 25 to 85 %
Altitude : 2000 m max.
Degree of protection : Front panel: IP66, Rear case: IP20, Terminal section: IP00
Memory protection : Non-volatile memory (number of writes: 1,000,000)
Case color : Black
Terminal type : Screw terminal block
Accessories : Mounting adapter, Waterproof packing, Front Port Cover
Weight : Main Unit: Approx. 250 g
Adapter: Approx. 4 g x 2
Sold separately : USB Serial Conversion Cable: E58-CIFQ2
Communications Conversion Cable: E58-CIFQ2-E
Terminal Cover: E53-COV24
Waterproof packing: Y92S-P10
Waterproof Cover: Y92A-96N
Front Port Cover: Y92S-P7
Adapter: Y92F-51
CX-Thermo Support Software: EST2-2C-MV4
Indication accuracy : Thermocouple: (±0.3% of indicated value or ±1 ℃, whichever is greater) ±1 digit max.
Platinum resistance thermometer: (±0.2% of indicated value or ±0.8 ℃, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
(The indication accuracy of K thermocouples in the -200 to 1300 ℃ range, T and N thermocouples at a temperature of -100 ℃ max., and U and L thermocouples at any temperatures is ±2 ℃ ±1 digit max. B thermocouple at a temperature of 400 ℃ max. is not specified. B thermocouples in the 400 to 800 ℃ range is ±3 ℃ max. R and S thermocouples at a temperature of 200 ℃ max. is ±3 ℃ ±1 digit max. C/W thermocouples is (±0.3% PV or ±3 ℃, whichever is greater) ±1 digit max. PL II thermocouples is (±0.3% PV or ±2 ℃, whichever is greater) ±1 digit max.)
Influence of temperature/voltage : Thermocouple: R, S, B, C/W, and PLII: (±1% of indicated value or ±10 ℃, whichever is greater) ±1 digit max.
Others: (±1% of indicated value or ±4 ℃, whichever is greater) ±1 digit max.. However K thermocouple at -100 ℃ max.: ±10 ℃ max.
Platinum resistance thermometer: (±1% of indication value or ±2 ℃, whichever is greater) ±1 digit max.
Analog input: ±1% FS ±1 digit max.
Ambient temperature: -10 to 23 to 55 ℃, Voltage range: -15 to 10% of rated voltage
Influence of EMS. : Thermocouple: R, S, B, C/W, and PLII: (±1% of indicated value or ±10 ℃, whichever is greater) ±1 digit max.
Others: (±1% of indicated value or ±4 ℃, whichever is greater) ±1 digit max.. However K thermocouple at -100 ℃ max.: ±10 ℃ max.
Platinum resistance thermometer: (±1% of indication value or ±2 ℃, whichever is greater) ±1 digit max.
Analog input: ±1% FS ±1 digit max.
Influence of signal source resistance : Thermocouple: 0.1℃/Ω max. (100 Ω max.)
Platinum resistance thermometer: 0.1℃/Ω max. (10 Ω max.)


Chúng tôi có hơn 35.000 sản phẩm vì vậy hãy liên hệ với chúng tôi
Để được tư vấn và check tình trạng hàng bạn nhé!

AUTO TECH VN cam kết:
1. Hàng Chính Hãng Autonics Việt Nam.
2. Xuất được Hóa đơn VAT.
3. Cấp CO/CQ công chứng bởi Autonics Vina.
4. Giá cạnh tranh.
5. Sản phẩm bảo hành theo chính sách của hãng.

AUTO TECH VN - AUT.VN

Thông tin liên hệ

ĐT/ Zalo : 0968.053.025
Email: support@aut.vn Email2: sale@aut.vn
Địa chỉ: 07 KĐT Flora Mizuki, Đường Số 1, Bình Hưng, Bình Chánh, Hồ Chí Minh
chỉ có thành viên mới được trả lời